Industrial
DC Motor Control Interface Board Module is an Original Manufacturing Engineering (OEM)
industrial and commercial rated high performance, high
efficiency function add to an exiting speed control driver.
The DC Motor Control Interface Board power of
10VDC or 12VD from your exiting Motor control board or external
power source. When 0 to 10VDC or 0 - 12VDC present in the input
from external controller the linear acceleration and
deceleration function will determine the ramp-up ramp-down time
that the output signal reach this particular voltage. For some
motor drive this signal is set via main speed Potentiometer
(POT), the board can accommodate it with additional function of
minimum setting for the external POT.
The board also contains induction LEDs for Power
On (PWR ON) and Current Limit (CL).
Shown above left, adjustments via
single turn trimmers (trimpot) and on the right with multi-turn trimmers
(MTT for high accuracy
Shown above DC Motor universal interface
board basic
connections illustration
Board basic functions:
Acceleration (ACCEL) Sets the amount of time (0.1
to 12 Sec.) for the motor to accelerate from zero speed to full
speed. It is equivalent to 0 to 10VDC that represent the full
speed.
Motor Acceleration Start: The board contains an
adjustable acceleration start feature which allows the motor to
smoothly accelerate from zero speed to full speed over a time
period of 0.1 to about 12 seconds. Acceleration Trimpot (ACCEL):
The ACCEL Trimpot is provided to allow for a smooth start over
an adjustable time period each time the AC power is applied or
the Main Speed Potentiometer (MSP) is adjusted to a higher
speed. The acceleration Trimpot (ACCEL) is factory set for 6
seconds. That is the amount of time it will take for the motor
to accelerate from zero speed to full speed. To increase the
acceleration time, rotate the ACCEL Trimpot clockwise. To
decrease the acceleration time, rotate the ACCEL Trimpot
counterclockwise.
Deceleration (DECEL), Sets the amount of time for
the motor to decelerate from full speed to zero speed. It is
equivalent to 10 to 0VDC that represent the minimum/zero speed.
Deceleration Trimpot (DECEL): The DECEL Trimpot
controls the amount of ramp-down time when the Main Speed
Potentiometer is adjusted to a lower speed. The DECEL Trimpot is
factory set to 6 seconds, that is the amount of time it will
take for the motor to decelerate from full speed to zero speed.
To increase the deceleration time, rotate the DECEL Trimpot
clockwise. To decrease the deceleration time, rotate the DECEL
Trimpot counterclockwise. The DECEL Trimpot range is 0.1 to
about 12 seconds. Please be advised that if the DECEL Trimpot is
set to greater than the natural coast time of the motor and
actual load, it will extend the deceleration time of the motor
Minimum (MIN.) Sets the minimum speed of the
motor. Usually set between 0 to 5VDC. Minimum Speed Trimpot
(MIN): The MIN Trimpot sets the minimum speed of the motor when
the Main Speed Potentiometer is set fully counterclockwise. The
MIN Trimpot is
factory set to 0% of base motor speed. To increase the minimum
speed,
rotate the MIN Trimpot clockwise. To decrease the
minimum speed, rotate the MIN Trimpot
counterclockwise. The MIN Trimpot range is 0% to about 30% of
base motor speed.
Please be advised, depending on driver from
different manufactures some motor speed control the MIN Trimpot
will affect the maximum speed setting. Therefore, it is
necessary to readjust the MAX Trimpot if readjusting the MIN
Trimpot. It may be necessary to repeat these adjustments until
both the minimum and maximum speeds are set to the desired
levels.
Indications/Diagnostic LEDs for both power On (PWR) and Current Limit (CL) signal.
Current Limit LED (CL): Will light and set open
collector transistor to drive relay via terminal block. The CL
Trimpot (not on board) is used to limit the maximum current
(torque) to the motor. The CL also protects the control from
excessive current during startup. The CL Trimpot usually
(manufacture depended) is set to 150% of the full load current
rating of the motor. To increase the current limit, rotate the
CL Trimpot clockwise (do not exceed 150% of the full load
current rating of the motor (maximum clockwise position)). To
decrease the current limit, rotate the CL Trimpot
counterclockwise. On cyclical loads, it may be normal for the CL
LED to momentarily flash. (Visible only if the cover is
removed.) The CL Trimpot range is 0% – 150% of the full load
current rating of the motor. Some application may require a
lower value so as not to damage process material or drive train
components.
The board offers the features
needed for professional ramping up or down your DC motor control.
Mounting is easy via four 0.125"
mounting holes using 4-40 screws and wire (optional) via
convenient conventional industrial standards Terminal Blocks
(TB).
Standard
Features:
● Provides motor with smooth
variable speed
●
Linear Adjustable
Deceleration
●
Linear Adjustable Acceleration
● Adjustable
Minimum (MIN) speed,
● High efficiency circuitry.
● Conveniently front mounted
terminal blocks.
● Conveniently front mounted LED
for both
power on and over current indicators.
Board
Dimensions:
Board width, length, height:
2.45" * 2.45" * 0.75".
Board
Mouthing Dimensions:
Four (4) mounting holes (.125"
Dia.) 2.100" * 2.100" on center.
Note:
Use four (4) 4-40 screws and stand-offs to mount the board.
Caution: Do not mount
the board where ambient temperature is outside the range of
-10° C (15° F) to 45° (115° F).
-20°C to +50°C (-4°F to 122°F).
Specifications:
Load current (continuous) |
< 100mA |
Motor Speed adjustment |
Potentiometer 0 to 10VDC or 0 to 12VDC
via 5K POT |
Acceleration |
0.1 to 12 seconds |
Deceleration |
0.1 to 12 seconds |
Minimum speed |
Adjustable - 0 to 30% of max speed |
Connections |
POT and wires via Terminal Block |
Operating temperature |
-20°C to +50°C (-4°F to 122°F) |
Board material |
FR4 |
Internal operating voltage |
About 12VDC model dependant |
Power Requirement |
10VDC or 12 VDC ±10% model
dependant at 200mA min. |
Model and Part
Number (P#) Selection:
Board only
MODEL P# |
INPUT VOLTAGE |
OUTPUT VOLTAGE |
Acceleration/Deceleration |
Adj. |
PIVOT-ACL-DEC-MIN-CL-10 |
0-10VDC |
0 - 10VDC |
12
seconds |
Trimpot |
PIVOT-ACL-DEC-MIN-CL-12 |
0-12VDC |
0 - 10 VDC |
12
seconds |
Trimpot |
PIVOT-ACL-DEC-MIN-CL-10-30 |
0-10VDC |
0 - 10VDC |
30
seconds |
Trimpot |
PIVOT-ACL-DEC-MIN-CL-12-30 |
0-12VDC |
0 - 10 VDC |
30
seconds |
Trimpot |
PIVOT-ACL-DEC-MIN-CL-MT-10 |
0-10VDC |
0 - 10VDC |
12
seconds |
MTT |
PIVOT-ACL-DEC-MIN-CL-MT-12 |
0-12VDC |
0 - 10 VDC |
12
seconds |
MTT |
PIVOT-ACL-DEC-MIN-CL-MT-10-30 |
0-10VDC |
0 - 10VDC |
30
seconds |
MTT |
PIVOT-ACL-DEC-MIN-CL-MT-12-30 |
0-12VDC |
0 - 10 VDC |
30
seconds |
MTT |
|